The BASELAYER CORE line delivers state-of-the-art raised floor space, configurable in standardized increments of predictable capacity indoors.

BASELAYER CORE PC10


CORE PC10 Power Module
The CORE PC10 Power Module is a state-of-the-art switchboard and UPS featuring modularized critical components and delivers a configurable conditioned power supply.
Unit PUE Range
As low as 1.15 (Dependent upon Environmental and Operational Conditions)

Module Power Delivery
2 x high Efficiency Uninterruptible Power Supply (UPS) provides conditioned Uninterruptible AC power.

Critical IT Capacity (kVA)
@N
1500 kVA
@N+1
750 kVA
@2N
750 kVA

Security
Access Control
Open Compartmentalized Architecture, Enhanced Security Encryption, Versatile Interoperability, Proximity Card Readers (Keypad and Biometric Options Available), Layers of Physical & Logical Protection, Separate IT & Support Space Access
Camera
IP Based Camera
Door Locks
Electronic Locks

Fire System
Dedicated Fire System
Externally Accessible Fire Control Panel, Pre-Discharge Alarm & Strobe Lights, Fire Pull Station, Abort Hold Button and Keyed Bottle Disconnects
Smoke Detection
Intelligent Photoelectric Smoke Sensors
Fire Suppression
Clean Agent Fire suppression (Non-Ozone Depleting Agent)
Fire Rating
NFPA 72 Compliant and UL-Listed Fire Equipment
Exterior Dimensions US(Metric)
Length Width Height
42’ 8” (13.0 m) 11’ 8” (3.5 m) 13’ 5” (4.0 m)

Exterior Dimensions US(Metric)
Length Width Height
42’ 8” (13.0 m) 11’ 8” (3.5 m) 13’ 5” (4.0 m)

Interior Dimensions US(Metric)
Length Width Height
42’ 0” (12.8 m) 11’ 0” (3.3 m) 8’ 5-1/2” (2.6 m)

Estimated Module Shipping Weight US(Metric)
78,000 lbs (35,380 kg) (Excludes storage batteries)

Input Power
Voltage/Frequency
480 V, Three-Phase, 60 Hz 400 V, Three-Phase, 50 Hz

UPS Type
Online, Double-Conversion, Transformer Free, Insulated-Gate Bipolar Transistor (IGBT) with Pulse-Width Modulation (PWM)

UPS Energy Storage
VRLA Battery Strings

Cooling Type
Chilled Water, Air Handling Units (AHU)

Leak Detection
Spot Leak Detection
core frontcore front
core frontcore front
core frontcore front

CORE DEPLOYMENT SCENARIO


BASELAYER CORE units are configurable in many deployment scenarios. This deployment delivers up to 1.2MW of Critical IT power and Cooling for up to fifty-four (54) 50U racks @ N redundancy.

BASELAYER deployments can consist of both power and data (IT) modules configured and tested from the factory with an enhanced integrated Module Control Unit (MCU) providing access to real-time module sensors. Power and cooling redundancy thresholds, along with analytics and historic trending, are all available through BASELAYER® RunSmart OS deployment module
SPECIFICATIONS & PERFORMANCE
Unit PUE Range
As low as 1.15
(Dependent upon Environmental and Operational Conditions)

Total Product Installation Footprint
3,207 ft2 (298.1m2)

Critical IT Footprint
1,386 ft2 (128.8m2)

Minimum Facility Ceiling Height
19’4″ ft (5.89m)

Access Control
Compartmentalized Architecture

Intelligent Control Interfaces
Customizable: Role Based Visibility, Warnings, Alarms, Thresholds & Control Set Points; BASELAYER RunSmart OS Integrates Both Modular and Legacy Data Center Infrastructure with IT Equipment

Dedicated Fire System
Each unit comes with an Externally Accessible Fire Control Panel and High Sensitivity Smoke

Available (UI) User Interface
Visualizer – Desktop and Mobile, Business Reporting, API Provide Real-time Visibility, Control, Optimization, and Automation

CE
Compliant
UL
UL 2755 Compliant
Uptime Institute
Product based on Tier III Design parameters
NFPA
Compliant